Compression load cells for weighing platforms, silos, hoppers etc..

Compression load cell

Upon request with ATEX or IECEx certification


Zoom Click to enlarge image

Compression load cell COL3 Compression load cell COL3 Schema
IECEX ATEX

Technical Specifications

MaterialStainless steel
Nominal load500, 1000, 1500 t
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageVcc 15 Max
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,1 % F.S.
Hysteresis0,1 % F.S.
Reapeatability0,1 % F.S.
Input resistance350-360 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,1 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4 / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / 10°C
Protection classIP 68
Standard cable lengthPanel male connector CR2R-07APNS (loose female connector CR2P-07ASNS-10), length to be defined
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

OptionalPanel male connector CR2R-07APNS
LengthCustom (body lead cell not connected shield)
Pin 1+ OUT
Pin 2- OUT
Pin 3NC
Pin 4NC
Pin 5NC
Pin 6+ IN
Pin 7- IN

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means